Process Measurement and Controls
Please contact Kube Engineering for Technical Information
|
 |

MTM/N10
Miniature
Bore Holes
50mV output |
STS Miniature
Depth/Level Transmitter
MTM/N10 Series
15
-
Fully submersible, 0.39" diameter
-
Ranges:Full Scale (Zero based)
-
0-15 psig to 0-150 psig
-
Other ranges and pressure units can be
specified.
-
0.25% & 0.5% accuracy
-
Material: 316L SS
-
Millivolt output signal
-
Analog output signals with
option: separate electronic circuitry
|

VL3000
Surface
Water
4-20mA
Current Output |
Versaline VL3000
Series Depth
and Level Pressure Transmitter
-
Ranges:Full Scale (Zero based)
-
0-10, 20, 30, 50” WC
-
0-1, 5, 10, 15, 30, 50, 100, 150, 200,
300 psig
-
0-50, 100, 150, 200, 300 psia
-
Other ranges and pressure units can be
specified.
-
0.1% & 0.25% accuracy
-
All welded 316L SS or Titanium
-
4-20 mA, 2 wire output
-
Molded polyurethane cable
|

VL4000
Groundwater/Sea Water
4-20mA
Output Titanium |
Versaline VL4000
Series Depth and Level Pressure Transmitter
-
Ranges:Full Scale
(Zero based)
-
0-10, 20, 30, 50” WC
-
0-1, 5, 10, 15, 30, 50, 100, 150, 200,
300 psig
-
0-50, 100, 150, 200, 300 psia
-
Other ranges and pressure units can be
specified.
-
0.1% & 0.25% accuracy
-
3/4" diameter
welded Titanium
-
4-20 mA, 2 wire output
-
Molded polyurethane cable
|

VL2000
Waste Water
4-20mA
Output
Ceramic
Capacitive Element |
Versaline VL2000 Series
Wastewater Level Transmitter
-
Ranges:Full Scale (Zero based)
-
0-10, 20, 30, 50” WC
-
0-1, 5, 10, 15, 30, 50, 100, 150 psig
-
Other ranges and pressure units can be
specified.
-
±0.25% Accuracy
-
All welded 316L SS or Titanium
-
4-20 mA, 2 wire output
-
Molded polyurethane cable
|

ATM/N/IS
Hazardous
Locations
4-20mA
Output
FM/CSA/IS |
ATM/N/IS Series
84
-
Fully submersible, 0.94" diameter
-
Ranges: Full Scale (Zero based)
0-40"WC to 0-360 psig
Other ranges and pressure units can be specified.
-
Accuracy: 0.1% & 0.25%
-
Material: 316L SS or Titanium
-
Output: 4-20 mA
-
FM/CSA approved for Class 1, Div. 1
|

Surface Water HART
Protocol
Re-Rangeable |
PMC-SMT/EL-CV/P-SUB
-
Ranges: 0
to
5" WC through 0
to
300 PSIG
-
Extremely rugged design
-
Double Sealed Housing
-
Hart® protocol
-
4-20 mA, 2 wire output
-
EMI/RFI protected
-
316L S/S housing with 10' cable, NEMA-4X
Standards
|

Ground Water Integrated
Datalogger |
DL/N Series
70
-
Fully submersible, 0.94" diameter
-
Ranges: Full Scale (Zero based)
0-40"WC to 0-360 psig
Other ranges and pressure units can be specified.
-
Accuracy: 0.1% & 0.25%
-
Material: 316L SS or Titanium
-
Measuring interval from 0.5 sec. - 24
hrs.
-
Conductivity with temperature module
-
Data memory for up to 500,000
measurements
-
Internal lithium battery
can be changed on site by the customer
|

Chemical Applications Submersible Pressure Transducer |
ATM NC Series 30
Comprehensive range to specifically designed for level
monitoring in chemical tank applications.
- 4-20mA
- Kevlar, EPDM or Teflon seals
- Kynar housing
|
 |
|
Smart Electronic Transmitters
|
|
PMC Smart Electronic Transmitters feature the remote
calibration of HART® protocol which allows for easy
access to the configuration and set-up of each
transmitter. |
|
 |
|
Precision Pressure Transmitters
|
|
Our broad range of precision pressure transmitters
and transducers offers analog or digital outputs.
Modular construction provides manufacturing
flexibility and offers fast delivery for all
pressure ranges and standard options |
|
 |
|
Seal Gauges, Switches & Gauge Panels
|
|
PMC Seal Gauges and Seal Switches are equipped with
proven PMC transmitter that accurately measure
pressures in industries where viscous materials are
processed. The Remote Gauge Panel System offers the
display of pressure readings in an accessible
location for ease of monitoring and adjustment.
|
|
 |
|
Pneumatic Transmitters
|
|
PMC Miniature Pressure and Level Transmitters offer
accurate measurement of pressure and levels
featuring our patented flush-mounted design. 3A
sanitary option also available. |
|
| |
|

Dri-Box Termination Enclosure |

Submersible Pressure
Transmitter Sink Weight |
| |
|
|
|
| |
|
|
|
| |
|
|
|