For over 25 years, Blancett has manufactured rugged and accurate
stainless steel turbine flow meters. Originally designed for the
North American oil industry, today Blancett turbines serve
customers in petrochemical, semiconductor, food and beverage and
process control industries throughout the world. |
|
Model 1100
Series Turbine Flow Meter |
| |


The
Blancett Model 1100 Turbine Flow
Meter is designed to meet the
demands of the most rigorous
flow measurement applications.
Originally developed for the
secondary oil recovery market,
the Model 1100 is an ideal meter
for liquid flow measurement on
or off the oilfield. The meter
features a 316 stainless steel
housing and rotor support,
CD4MCU stainless steel rotor,
and abrasion-resistant tungsten
carbide rotor shaft and journal
bearings. These materials help
the meter to maintain accuracy
and mechanical integrity when
measuring the corrosive and
abrasive fluids found in many
industries.
Click here to download the
Model 1100 Turbine Flow Meter
Technical Data Sheet (1.01 MB).

Fluid entering the meter first
passes through an inlet flow
straightener that reduces its
turbulent flow pattern. Fluid
then passes through the turbine,
causing the turbine to rotate at
a speed proportional to fluid
velocity. As each turbine blade
passes through the magnetic
field generated by the meter's
magnetic pick-up, an AC voltage
pulse is generated. These
pulses provide an output
frequency that is proportional
to volumetric flow.
|
Accuracy: |
±1% of
reading for 7/8" and
larger meters;
±1% of reading over the
upper 70% of the
measuring range for
3/8", 1/2" and 3/4"
meters |
|
Repeatability: |
±0.1% |
|
Operating
Temperature: |
-150 °F
to +350 °F (-101 °C to
+177 °C) standard
Temperatures to +425 °F
(+232 °C) with high-temp
pick-up |
|
Turndown Ratio: |
About
10:1 |
|
End Connections: |
NPT,
BSP, Flange, Grooved End
(Victaulic®),
Grayloc® |
|
Part # |
Bore Size |
End Connections |
Max PSI. |
Flow Ranges |
Approx.
K-Factor
Pulses/Gal |
|
GPM |
BPD |
|
B110-375-1/2 |
3/8" |
1/2" x 1/2" male NPT |
5,000 |
.6-3 |
20-100 |
20,000 |
|
B110-500-1/2 |
1/2" |
1/2" x 1/2" male NPT |
5,000 |
.75-7.50 |
25-250 |
11,500 |
|
B110-750-1/2 |
3/4" |
1/2" x 1/2" male NPT |
5,000 |
2-15 |
68-515 |
3,300 |
|
B110-375 |
3/8" |
1" x 1" Male NPT |
5,000 |
.6-3 |
20-100 |
20,000 |
|
B110-500 |
1/2" |
1" x 1" Male NPT |
5,000 |
.75-7.50 |
25-250 |
11,500 |
|
B110-750 |
3/4" |
1" x 1" Male NPT |
5,000 |
2-15 |
68-515 |
3,300 |
|
B110-875 |
7/8" |
1" x 1" Male NPT |
5,000 |
3-30 |
100-1000 |
3,100 |
|
B111-110 |
1" |
1" x 1" Male NPT |
5,000 |
5-50 |
170-1700 |
870 |
|
B111-115 |
1-1/2" |
1.5" x 1.5" Male NPT |
5,000 |
15-180 |
515-6000 |
310 |
|
B111-121 |
1-1/2" |
2" x 2" Male NPT |
5,000 |
15-180 |
515-6000 |
310 |
|
B111-120 |
2" |
2" x 2" Female NPT |
5,000 |
40-400 |
1300-13000 |
52 |
|
B311-004 |
3" |
3" x 3" Male NPT |
2,000 |
60-600 |
2100-21000 |
57 |
|
B111-130 |
3" |
Grooved End |
800 |
60-600 |
2100-21000 |
57 |
|
B311-084 |
4" |
4" x 4" Male NPT |
1,500 |
100-1200 |
3400-41000 |
29 |
|
B111-140 |
4" |
Grooved End |
800 |
100-1200 |
3400-41000 |
29 |
|
B311-085 |
6" |
6" x 6" Male NPT |
1,000 |
200-2500 |
6800-86000 |
7 |
|
B111-160 |
6" |
Grooved End |
800 |
200-2500 |
6800-86000 |
7 |
|
B111-180 |
8" |
Grooved End |
800 |
350-3500 |
12000-120,000 |
3 |
|
B111-200 |
10" |
Grooved End |
800 |
500-5000 |
17143-171,423 |
1.6 |
|
|
|
|
|
|
QuikSert In-Line Turbine
Flow Meter |


The
Blancett QuikSert In-line
Turbine Flow Meter provides the
high accuracy and rigorous
design of the standard Blancett
turbine, but in a wafer-style
mounting configuration. With a
unique "between-the-flange"
design, the need for mating
flanges is eliminated, saving
installation time and cost, and
allowing for limited space
requirements. The meter
features a 316 stainless steel
housing and rotor support,
CD4MCU stainless steel rotor,
and abrasion-resistant tungsten
carbide rotor shaft and journal
bearings. Precision upstream
and downstream flow
straighteners ensure a high
degree of measurement accuracy.
Click here to download the
QuikSert Flow Meter Technical
Data Sheet (1.06 MB).

Fluid entering the meter first
passes through an inlet flow
straightener that reduces its
turbulent flow pattern. Fluid
then passes through the turbine,
causing the turbine to rotate at
a speed proportional to fluid
velocity. As each turbine blade
passes through the magnetic
field generated by the meter's
magnetic pick-up, an AC voltage
pulse is generated. These
pulses provide an output
frequency that is proportional
to volumetric flow.
|
Accuracy: |
±1% of
reading for 7/8" and
larger meters;
±1% of reading over the
upper 70% of the
measuring range for
3/8", 1/2" and 3/4"
meters |
|
Repeatability: |
±0.1% |
|
Operating
Temperature: |
-150 °F
to +350 °F (-101 °C to
+177 °C) standard
Temperatures to +425 °F
(+232 °C) with high-temp
pick-up |
|
Turndown Ratio: |
About
10:1 |
|
End Connections: |
Wafer-style, ASME/ANSI
B16.5-1996 |
|
Part Number |
Meter Size x
Flange Size |
Flow Ranges GPM |
Flow Ranges BPD |
Typical K-factor
pulses/gallon |
|
B131-038 |
3/8" x 1" |
0.60 - 3.00 |
20-100 |
18,000 |
|
B131-050 |
1/2" x 1" |
0.75-7.50 |
25-250 |
13,000 |
|
B131-075 |
3/4" x 1" |
2.0-15.0 |
68-515 |
3,300 |
|
B131-088 |
7/8" x 1" |
3.0-30.0 |
100-1000 |
3,100 |
|
B131-100 |
1" x 1" |
5.0-50.0 |
170-1700 |
870 |
|
B132-050 |
1/2" x 2" |
0.75-7.50 |
25-250 |
13,000 |
|
B132-075 |
3/4" x 2" |
2.0-15.0 |
68-515 |
3,300 |
|
B132-088 |
7/8" x 2" |
3.0-30.0 |
100-1000 |
3,100 |
|
B132-100 |
1" x 2" |
5.0-50.0 |
170-1700 |
870 |
|
B132-150 |
1-1/2" x 2" |
15-180 |
515-6000 |
310 |
|
B132-200 |
2" x 2" |
40-400 |
1,300-13,000 |
48 |
|
B133-300 |
3 x 3" |
60-600 |
2,100-21,000 |
57 |
|
B134-400 |
4" x 4" |
100 - 1,200 |
3,400 - 41,000 |
29 |
|
B136-600 |
6" x 6" |
200 - 2,500 |
6,800 - 86,000 |
7 |
|
B138-800 |
8" x 8" |
250 - 3,500 |
8,500-120,000 |
3 |
|
B139-900 |
10" x 10" |
500 - 5,000 |
17,150-171,500 |
1.6 |
|
|
|
|
|
| FloClean Sanitary Turbine
Flow Meter |

The
Blancett FloClean Sanitary
Turbine Flow Meter provides the
high accuracy and rigorous
design of the standard Blancett
turbine in a sanitary-style
tri-clamp mounting
configuration. Developed for use
in a variety of food, beverage
and pharmaceutical applications,
the FloClean Sanitary Turbine
meets the requirements of 3-A
Sanitary Standard number 28-03
and is suitable for use in
clean-out-of-place (COP) and
sterilize-out-of-place (SOP)
environments. The meter features
a 316L stainless steel body and
internal wetted parts, with
nickel-plated CD4MCU stainless
steel turbine and tungsten
carbide rotor shaft.
Click here to download the
FloClean Sanitary Turbine Flow
Meter Technical Data Sheet (887
KB).
Click here to download the
3A Approval Certificate (444
KB).

Fluid entering the meter first
passes through an inlet flow
straightener that reduces its
turbulent flow pattern. Fluid
then passes through the turbine,
causing the turbine to rotate at
a speed proportional to fluid
velocity. As each turbine blade
passes through the magnetic
field generated by the meter's
magnetic pick-up, an AC voltage
pulse is generated. These pulses
provide an output frequency that
is proportional to volumetric
flow.
|
Accuracy: |
±1% of
reading |
|
Repeatability: |
±0.1% |
|
Operating
Temperature: |
-150 °F
to +300 °F (-101 °C to
+149 °C) standard |
|
Mag Pick-up: |
NEMA 6 |
|
End Connections: |
Sanitary Clamp End |
|
Clamp Size |
Meter Size |
Flow Ranges GPM |
Flow Ranges LPM |
Typical K-Factor
Pulses/Gallon |
|
3/4" |
3/8" |
0.60-3.00 |
2.3-11.4 |
20,000 |
|
3/4" |
1/2" |
0.75 - 7.50 |
2.8 - 28.4 |
13,000 |
|
3/4" |
3/4" |
2.0 - 15.0 |
7.5 - 56.8 |
2,750 |
|
1.5" |
1/2" |
0.75 - 7.50 |
2.8 - 28.4 |
13,000 |
|
1.5" |
3/4" |
2.0 - 15.0 |
7.5 - 56.8 |
2,750 |
|
1.5" |
7/8" |
3.0 - 30 |
11.4 - 113.5 |
2,686 |
|
1.5" |
1" |
5.0 - 50.0 |
19.0 - 190.0 |
870 |
|
1.5" |
1.5" |
15 - 180 |
56.8 - 681.4 |
330 |
|
2.5" |
2" |
40 - 400 |
151.4 - 1514.2 |
52 |
|
|
|
|
|
|
Model 1200 |

The
Blancett Model 1200 In-Line
Turbine Flow Meter was
engineered for applications in
high corrosive environments.
Developed for use in
petrochemical and other process
industries with liquid chemical
flows, the Model 1200 Turbine
provides accuracy and durability
in aggressive industrial
environments. The meter features
a 303 stainless steel body and
internal wetted parts, with two
Type 440 stainless steel ball
bearings.

Fluid entering the meter passes
through an inlet flow
straightener and a
hydrodynamically shaped
deflector cone to reduce its
turbulent flow pattern. Fluid
then passes through the turbine,
causing the turbine to rotate at
a speed proportional to fluid
velocity. The rotating turbine
blades modulate a high frequency
carrier wave in the
externally-mounted RF pick-up.
|
Accuracy: |
±0.5%
of reading |
|
Repeatability: |
±0.1% |
Operating
Temperature:
Meter
RF Preamp |
-60 °F to +350 °F (-51
°C to +177 °C)
-20 °F to +160 °F (-29
°C to +71 °C) |
|
Output: |
RF
Preamp; 10Vp-p, zero
referenced square wave |
|
End Connections: |
NPT |
|
Part # 1 |
Meter Size |
End Connection |
Max PSI |
Flow Ranges |
Approx.
K-Factor
Pulses/Gal |
|
GPM |
LPM |
|
B121-225 |
1/4" |
1/2" male NPT |
4,000 |
0.25-2.5 |
0.57-9.46 |
29,000-33,000 |
|
B121-250 |
1/2" |
1/2" female NPT |
4,000 |
0.75-7.5 |
0.95-28.39 |
8,500-9,500 |
|
B121-275 |
3/4" |
1" male NPT |
4,000 |
2.5-25 |
1.89-94.64 |
2,800-3,000 |
1 Includes
B1111117 RF pick-up, 10
ft Teflon®
cable assembly with 90°
connector,
and 12/24 VDC
preamplifier |
|
|
|
|
|
|
SERIES 200 & 900 |

The
Blancett Series 200 and Series
900 are rugged, low-priced flow
meters specifically designed to
measure floodwater line flow in
secondary oil recovery
operations throughout the world.
Using time-proven rotary vane
and multi-jet impeller
mechanisms, the Series 200 and
900 flow meters will provide
reliable long-term measurement
and totalization with minimum
attention and maintenance.
Click here to download the
Series 200 & 900 Flow Meter
Technical Data Sheet (2.80 MB).

The Series 900 features
interchangeable inlet inserts
with three different sized
orifices. The orifices are
pre-calibrated for specific low,
medium and high flow ranges of
the meter. Fluid enters the
inlet port and passes through
the pre-selected orifice into
the cylindrical measuring
chamber. Here, the flowing fluid
is separated into two streams,
rotating a vaned impeller at a
speed directly proportional to
flow rate. The impeller is
connected to a meter register
through a magnetic drive
assembly. Each impeller rotation
is mechanically tabulated and
displayed by the register atop
the meter.
|
Accuracy: |
±2% of
reading |
|
Flow Ranges: |
Low:
68-172 barrels per day
Mid: 172-1543 barrels
per day
High: 1543-3086 barrels
per day |
|
Operating
Temperature: |
+30 °F
to +200 °F (-1 °C to +93
°C) |
|
Pressure rating: |
5,000
psi maximum |
|
End Connections: |
1" NPT
(female), 2" NPT (male) |

The Series 200 features a radial
vaned impeller, mounted on a
vertical spindle within a
cylindrical measuring chamber.
Fluid entering the meter passes
through the lower compartment of
the central housing, and then
enters the measuring chamber
through several tangential
orifices located around the
cylinder. The flowing water
causes the impeller blades to
rotate at a speed directly
proportional to flow rate. The
rotating impeller is
magnetically coupled to a
mechanical register, and each
impeller rotation is
mechanically tabulated and
displayed.
|
Accuracy: |
±1% of
reading |
|
Flow Ranges: |
5-685
barrels per day
(approximately .15 - 20
GPM) |
|
Operating
Temperature: |
+30 °F
to +200 °F (-1 °C to +93
°C) |
|
Pressure rating: |
1,000
psi maximum |
|
End Connections: |
1" NPT
(female) |
|
|
|
|
|
|